{"repo":"NousResearch/hermes-agent","public_id":"90778","display_label":"Fix venv holder message labels and parsing","summary":"These items address incorrect labeling and substring-matching issues in the venv holder CLI message, specifically around how the dashboard hint and standalone dashboard holders are identified and displayed.","subsystem":"hermes_cli","counts":{"members":4,"open_issues":0,"open_issues_distinct":0,"open_prs":0,"closed_issues":1,"merged_prs":1,"attempt_prs":2},"landed_fix":{"status":"merged_to_main","basis":"structural","pr":91869,"merged_at":"2026-08-22T02:11:56+00:00"},"resolution":{"state":"resolved","by":"pr-91869"},"freshness":{"state":"verified","last_verified_at":"2026-08-22T02:11:56+00:00","is_stale":false},"grouping":{"backbone":"STRUCTURAL_SPANNING","link_density":0.5},"fix_edges":[{"issue_number":77277,"pr_number":91869,"tier":"verified","basis":"superseded_ref","confidence":0.9,"recoverable_from_timeline":false,"pr_merged_at":"2026-08-22T02:11:56+00:00"},{"issue_number":90778,"pr_number":91869,"tier":"verified","basis":"closing_ref","confidence":0.95,"recoverable_from_timeline":true,"pr_merged_at":"2026-08-22T02:11:56+00:00"}],"members":[{"kind":"issue","number":90778,"title":"Windows venv-holder message mislabels `hermes dashboard` as the Desktop backend, and matches subcommands by substring","url":null,"state":"closed"},{"kind":"pr","number":90791,"title":"fix(cli): label standalone dashboard holders correctly in the venv message","url":null,"state":"closed","close_reason":{"refs":[{"kind":"pr","value":"#91869","number":91869},{"kind":"pr","value":"#90778","number":90778},{"kind":"pr","value":"#91277","number":91277}],"category":"superseded_by_pr","implication":"superseded"},"merged":false},{"kind":"pr","number":91490,"title":"fix(cli): parse tokens in venv python holders message and separate dashboard hint","url":null,"state":"closed","close_reason":{"category":"implemented_elsewhere","implication":"superseded"},"merged":false},{"kind":"pr","number":91869,"title":"fix(update): Windows venv-holder guard names holders correctly and can see the gateway it must pause (#90778, #87594 — proven live on windows-latest)","url":null,"state":"merged","close_reason":{"category":"merged"},"merged":true,"is_fix_pr":true,"fix_tier":"verified","files_changed":[".github/workflows/windows-venv-e2e.yml","hermes_cli/update_cmd.py","tests/gateway/test_goal_resume_restart.py","tests/hermes_cli/test_venv_holder_classifier.py","tests/hermes_cli/test_venv_holder_windows_live.py"]}],"trust":{"default_tier":"verified","includes_suggested":false}}